Gigabit PoE Media Converter | OmniConverter GPoE/SE Gigabit PoE Media Converter | OmniConverter GPoE/SE SFPs not included
OmniConverter® GPoE+/S

10/100/1000 Media Converter with Power over Ethernet (PoE/PoE+) Enhanced Version*



Features


  • IEEE 802.3af/at multi-port Gigabit Media Converter
  • Compact size
  • Dual Device mode for operating as two separate media converters
  • Directed Switch mode prevents flooding of multicast video traffic
  • Configurable PoE Power Reset
  • Uplink redundancy on models with two uplink ports
  • Two SFP or two 10/100/1000 RJ-45 uplink ports
  • Supports 10/100/1000 and 1G copper SFP transceivers
  • Supports 100Mbps and 1000Mbps fiber SFPs
  • One ST or SC fixed Gigabit fiber connectors
  • One or two 10/100/1000 RJ-45 PoE/PoE+ user ports
  • Commercial (0º to 50ºC), wide (-40º to 60ºC) and extended (-40º to 75ºC) operating temperature ranges
  • TAA, BAA and NDAA compliant, and Made in the USA
  • Lifetime Warranty and free 24/7 Technical Support




Description


The OmniConverter GPoE+/S are multi-port IEEE 802.3at PoE+ Ethernet media converters that feature one or two uplink ports and one or two 10/100/1000 RJ-45 PoE+ user ports.

The GPoE+/S provides up to 30W PoE+ per RJ-45 user port and supports frame sizes up to 10,240 bytes. The uplink ports can be fixed fiber or SFP receptacle or 10/100/1000 RJ-45 copper ports.

The GPoE+/S supports Directed Switch mode, which directs multicast traffic (such as video) only to the appropriate uplink port, preventing the multicast video traffic from flooding other network ports.

Models with two fiber port support redundant fiber uplinks for critical applications that require protection and restoration in the event of a fiber failure. The second fiber port can also be used to cascade multiple media converters.

Models with two fiber ports also support Dual Device mode that enables the module to operate as two independent and isolated Ethernet media converters. In Dual Device mode, the GPoE+/S provides separate and independent data traffic paths between the two uplink ports and two user ports.

Configurable features include link modes and a PoE power reset function that enables the attached PD device, such as a camera or access point, to be re-initialized remotely, eliminating the need for costly truck rolls to remote PD sites. When a problem with a PD is detected, the fiber port on the module can be disconnected, triggering the PoE power reset function.

Link modes can be configured to propagate loss-of-link faults to managed devices, immediately notifying administrators of network outages.

The GPoE+/S support fixed-fiber connectors and 100Mbps or 1000Mbps SFP transceiver receptacles, enabling easy adaptability to different fiber types, distances and wavelengths. The media converters also support 10/100/1000 SGMII or 1Gbps SERDES copper transceivers and 100Mbps and 1000Mbps standard, CWDM and DWDM fiber transceivers in a variety of distances and fiber types.

The GPoE+/S can be tabletop mounted, wall mounted, or DIN-rail mounted using an optional DIN-rail mounting kit. They can also be mounted on a 1U 19” rack-mount shelf. They are available with DC input power via terminal connectors or an external 100 to 240V AC power adapters.





Examples


Dual Device Mode Application

This Dual Device feature is extremely useful when two isolated networks domains share a single network distribution location. The example below depicts a scenario where a surveillance security (green) network and a Wi-Fi (purple) network are sharing a single hub distribution location.

Using the two uplinks and the Dual Switch mode facilitates using a single PoE media converter driving both the Cameras and the Wi-Fi Access Points while maintaining isolation between the networks.

Dual Device Mode GPoE S

 

Daisy Chain Application

This example demonstrates the daisy chain capabilities of the OmniConverter media converters. In this application each media converter connects to its neighboring converter via its uplink ports. The daisy chain can continue to additional converter using this method of connectivity.

Each OmniConverter media converter provides connectivity to the fiber links, and power to IP cameras and Wi-Fi access points at each location along the daisy chain.

Daisy Chain App gpoe s





Specifications


Description
OmniConverter® GPoE+/S
10/100/1000BASE-T to 1000BASE-X or 100BASE-X Fiber Media Converter with PoE+
Standard Compliances

IEEE 802.3,

IEEE 802.3af (15.40 watts max), IEEE 802.3at (30 watts max)

Regulatory Compliances
(Pending)

Safety: UL 62368-1, UL 60950-1,

             IEC 62368-1, IEC 60950-1,

             EN 62368-1, EN 60950-1,

             CAN/CSA C22.2 No. 62368-1-14, CAN/CSA C22.2 No. 60950-1,

             CE Mark,

             UKCA

EMC:   EN 55032/24 CE Emissions/Immunity,

             IEC 61000-6-4 Industrial Emissions,

             IEC 61000-6-2 Industrial Immunity

EMI:      CISPR 32,

             FCC 47 Part 15 Subpart B Class A

EMS:    IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV,

             IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m,

             IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV (DC models),

             IEC 61000-4-4 EFT: Power: 1 kV; Signal: 1 kV (AC models),

             IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV (DC models),

             IEC 61000-4-5 Surge: Power: 1 kV Line/Line; 2 kV Line/Gnd; Signal: 2 kV (AC models),

             IEC 61000-4-6 CS: Signal: 10 V,

             IEC 61000-4-8 (Magnetic Field) 30A/m, IEC 61000-4-11 (Voltage Dips, interrupts)

IP Rating: IP30D Protection

ACT: TAA, BAA,NDAA

Environmental
RoHS, WEEE, REACH
PoE Power Modes
IEEE Alterative A (Alt A)
Frame Size
Up to 10,240 bytes
Port Types:

Copper: 10/100/1000BASE-T (RJ-45)

Fiber:     100BASE-X (SFP), 1000BASE-X (ST, SC, LC, SFP),

              10/100/1000 SGMII (RJ-45 SFP), 1G SERDES (RJ-45 SFP)

Cable Types

Copper: EIA/TIA 568A/B, Cat 5 UTP and higher

Fiber:     Multimode: 50/125, 62.5/125µm

               Single-mode: 9/125µm

AC Power Requirements
(Models with AC/DC Adapters)

1 RJ-45 Port

100 - 240VAC/50 to 60Hz

0.33A @ 120VAC (typical)

2 RJ-45 Ports

100 - 240VAC/50 - 60Hz

0.62A @ 120VAC (typical)

DC Power Requirements
(Models with DC Terminals)

1 RJ-45 Port

+/-46 to +/-57VDC;

0.62A @ 56VDC

2 Pin Terminal (isolated)

2 RJ-45 Ports

+/-46 to +/-57VDC;

1.16A @ 56VDC

2 Pin Terminal (isolated)

A minimum DC input voltage of 50VDC is required to guarantee 25.5 watts (802.3at) at the end of 100 meters of Cat 5 or better
Dimensions (W x D x H) 3.8” x 4.8” x 1.0” (96.5 mm x 121.9 mm x 25.4 mm)
Weight

Module Only: 1.0 lbs. (453.6 grams)

Module w/ Adapter: 1.9 lbs. (852.6 grams)

Operating Temperature
(See Temperature Derating Table)

Commercial: 0 to 50°C

Wide:         -40 to 60°C (-20°C AC cold start)

Extended: -40 to 75°C (-20°C AC cold start) 

Storage:    -40 to 80°C

Humidity 5 to 95% (non-condensing)
Altitude -100m to 4,000m
MTBF (hours)

Module Only: 584,000

AC/DC Adapter: 100,000

Warranty Lifetime warranty with 24/7/365 free Technical Support

 

 

Power / Voltage Requirements and Specifications per IEEE

 
Description IEEE 802.3af PoE IEEE 802.3at PoE+
Power Supply Voltage Range 46.0 to 57.0 VDC 51.0 to 57.0 VDC
Voltage Range at PSE port Output 44.0 to 56.0 VDC 50.0 to 56.0 VDC
Maximum Power from PoE/PSE port 15.4 watts 30 watts
Minimum Voltage at PoE/PD port input* 37.0 VDC 42.5 VDC
Minimum Power at PoE/PD port* 12.95 watts 25.5 watts




Ordering


The previous/old version of the GPoE/S and GPoE+/S are no longer in production. GPoE/S models 9400 - 9419 and GPoE+/S 9420 - 9439 are replaced with the enhanced models below.

 

Step 1: Choose a Base Part Number (xxxxN-x-ypt)

Fiber TypeDistanceConnector Type

Tx / Rx

Lambda

(nm)

Min. Tx

Power

(dBm)

Max. Tx

Power

(dBm)

Min. Rx

Power

(dBm)

Max. Rx

Power

(dBm)

Min

Attenuation

(dB)

Link
Budget

(dB)

STSCSFPRJ-45
MM/DF 220/550m1 9420N-0-ypt 9422N-0-ypt - - 850 / 850 -10 -4 -17 -3 - 7
MM/DF (x2) 220/550m1 - - - - 850 / 850 -10 -4 -17 -3 - 7
SM/DF 12km 9421N-1-ypt 9423N-1-ypt - - 1310 / 1310 -9.5 -3 -19.5 -3 - 10
SM/DF (x2) 12km - - - - 1310 / 1310 -9.5 -3 -19.5 -3 - 10
SM/DF 34km 9421N-2-ypt 9423N-2-ypt - - 1310 / 1310 -9.5 -3 -19.5 -3 - 10
SM/DF 80km - 9423N-3-ypt - - 1550 / 1550 -5 0 -23 -3 3 18
SM/DF 110km - 9423N-4-ypt - - 1550 / 1550 0 5 -24 -3 8 24
SM/DF 140km - 9423N-5-ypt - - 1550 / 1550 2 5 -28 -8 13 30
MM/SF2 550m - 9430N-0-ypt - - 1310 / 1550 -9 -3 -18 -3 - 9
MM/SF2 550m - 9431N-0-ypt - - 1550 / 1310 -9 -3 -18 -3 - 9
SM/SF2 20km - 9430N-1-ypt - - 1310 / 1550 -9.5 -3 -20 -3 - 10.5
SM/SF2 20km - 9431N-1-ypt - - 1550 / 1310 -9.5 -3 -20 -3 - 10.5
SM/SF2 40km 9430N-2-ypt - - 1310 / 1550 -3 0 -20 -3 3 17
SM/SF2 40km  - 9431N-2-ypt - - 1550 / 1310 -3 0 -20 -3 3 17
RJ-45 (x1) 100m  -  - - 9438N-0-ypt - - - - - - -
RJ-45 (x2) 100m  -  - - 9438N-1-ypt - - - - - - -
SFP (x1) -  -  - 9439N-0-ypt - - - - - - - -
SFP (x2) -  -  - 9439N-1-ypt - - - - - - - -
1 62.5/125µm, 100/140µm multimode fiber up to 220m. 50/125µm multimode fiber up to 550m.
2 When using single-fiber (SF) models, the Tx wavelength on one end has to match the Rx wavelength on the other.
MM = Multimode, SM = Single-mode, DF = Dual Fiber, SF = Single-fiber
Contact Omnitron for other fiber options. Order the appropriate SFPs separately. Visit the Optical Transceivers web page.
Contact Omnitron for conformal coating options.

Step 2: Choose the number of RJ-45 ports (xxxxN-x-ypt) 

1 = One RJ-45 Ports
2 = Two RJ-45 Ports

Step 3: Choose a Power Option (xxxxN-x-ypt)

1 = External AC/DC Adapter, 100 - 240 VAC included, with US Power Cord
2 = External AC/DC Adapter, 100 - 240 VAC included, No Power Cord
8 = External AC/DC Adapter, 100 - 240 VAC included, PS JET/PSE Certified, with Japanese Power Cord
9 = Direct DC 2 pin terminal connector, no AC/DC power adapter

Step 4: Choose an Operating Temperature Range Option (xxxxN-x-ypt)

<leave blank> = Commercial temperature (0 to 50°C)
W = Wide temperature (-40 to 60°C)
Z = Extended temperature (-40 to 75°C) -  Check the Derating Table for available wattage for models with AC/DC Power Adapter

 

 

AC/DC Adapter Temperature Derating - Total Available Wattage to RJ-45 Ports
Model RJ-45 Ports Watts Required

Watts Available

@40°C

Watts Available

@50°C

Watts Available

@60°C

Watts Available

@70°C

Watts Available

@75°C

GPoE+/S 1 30 watts Full Power Full Power Full Power Full Power Full Power
2 60 watts Full Power Full Power Full Power Full Power 50 watts
The AC/DC Adapter Temperature derating table is not applicable to models with DC Terminal (see Ordering table for Direct DC power option 9). The DC Terminal models will provide full PoE power over the operating temperature range of the module as long as the DC input voltage meets the requirements stated in the specification table.

 

 

Accessories

Model Number
Description
8250-0
DIN-Rail Mounting Bracket
8251-0
DIN-Rail Mounting Clip
8260-0
19" rack mount shelf

 

 

*MODEL COMPARISON

Previous/Old Base Model #Previous/Old Model Enhanced Base Model #Enhanced Model
9400 GPoE/S 15 W per RJ-45 User Port 9420N GPoE+/S 30 W per RJ-45 User Port
9420 GPoE+/S 30 W per RJ-45 User Port

 

Features

Previous/Old Model

GPoE/S and GPoE+/S

Enhanced Model

GPoE+/S

Benefits
Copper Uplink Ports N/A One or two ports Product flexibility
RJ-45 SFP Support

N/A

10/100/1000 SGMII

1G SERDES

Allows for multiple SFP transceiver options
Dimensions (W x D x H)

4.5” x 6.0” x 1.0”

3.8” x 4.8” x 1.0” Compact size
PoE Power Level

IEEE 802.3af - GPoE/S

IEEE 802.3af/at - GPoE+/S

IEEE 802.3af/at 15W and 30W versions in one model
Dual Device Mode

N/A

Models with dual uplink ports Two independent and isolated Ethernet media converters
Directed Switch Mode

N/A

Prevents multicast (video) traffic from flooding other network ports
Legacy pre-IEEE Power Standards

Alternative A Power Mode

No configuration for the user
IP Protection

IP20

IP30D Provides increased enclosure protection