Main Menu
Useful Links
Contact us
Follow us
© 2024 Omnitron Systems Technology, Inc. All Rights Reserved. | Privacy Policy
The RuggedNet GHPoEBT/Si replaces the GHPoE/Si and is recommended for all new designs.
The RuggedNet GHPoEBT/Si are industrial ruggedized unmanaged Ethernet switches that feature fiber or copper uplink ports and four 10/100/1000 RJ-45 copper Power-over-Ethernet user ports.
The GHPoEBT/Si is an IEEE 802.3bt switch featuring 60W and 100W per user port models.
The RuggedNet PoE switches are standard Layer 2 Ethernet switches that forward frames to any port based on their MAC address.
All models support Directed Switch mode, which directs multicast traffic (such as video) only to the appropriate uplink port, preventing multicast traffic from flooding other network ports.
Models with two fiber or two copper uplink ports support daisy-chain configurations or redundant uplinks for critical applications that require protection and sub 50ms restoration in the event of an uplink failure.
Models with two fiber or two copper uplink ports also support Dual Device mode that enables the switches to operate as two independent and isolated Ethernet switches. In Dual Device mode, the switches provide separate and independent data traffic paths between each uplink and a pair of user ports.
Models are available with fixed ST, SC, and LC fiber connectors or Small Form Pluggable (SFP) transceiver receptacles. Fiber ports support multimode or single-mode and dual fiber or single-fiber with distances up to 140km. SFP models support a variety of distances in standard, CWDM and DWDM wavelengths.
The switches automatically negotiate and deliver the power level required by a Powered Device (PD) partner. Depending on the model of the RuggedNet PoE switch, the switch can deliver up to 60 or 100 Watts of power per user port.
The RuggedNet switches feature a remote PoE power reset function that can be configured with a DIP-switch. This feature allows all PDs to be power-cycled and reset remotely.
All models can be wall or rack mounted using a wall mount bracket and shelf or DIN-rail mounted using the included DIN-rail mounting clip. They are available with single or dual DC input power options.
Dual Device Mode Application
This Dual Device feature is extremely useful when two isolated networks domains share a single network distribution location. The example below depicts a scenario where a surveillance security (purple) network and a Wi-Fi (green) network are sharing a single hub distribution location. Using the two uplinks and the Dual Switch mode facilitates using a single PoE switch driving both the Cameras and the Wi-Fi Access Points while maintaining isolation between the networks.
Daisy Chain Application
This example demonstrates the daisy chain capabilities of the RuggedNet PoE switches. In this application each RuggedNet switch connects to its neighboring switch via its uplink ports. The daisy chain can continue to additional switches using this method of connectivity.
Each RuggedNet switch provides connectivity to the fiber links, and power to IP cameras and Wi-Fi access points at each location along the daisy chain.
Description | RuggedNet® GHPoEBT/Si (60/100W BT) 10/100/1000BASE-T with Gigabit Fiber or Copper Uplinks Ruggedized Unmanaged IEEE 802.3bt PoE Ethernet Switch |
||
---|---|---|---|
Standard Compliances |
IEEE 802.3, IEEE 802.3af (15.40 watts max), IEEE 802.3at (30 watts max), IEEE 802.3bt (60 and 100 watts max) |
||
Regulatory Compliances |
Safety: UL 62368-1, UL 60950-1, IEC 62368-1, IEC 60950-1, EN 62368-1, EN 60950-1, CAN/CSA C22.2 No. 62368-1-14, CAN/CSA C22.2 No. 60950-1, CE Mark, UKCA EMC: EN 55032/24 CE Emissions/Immunity, IEC 61000-6-4 Industrial Emissions, IEC 61000-6-2 Industrial Immunity EMI: CISPR 32, FCC 47 Part 15 Subpart B Class A EMS: IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV, IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m (on UTP cabling) and 20 V/m (on STP cabling) IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV, IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV, IEC 61000-4-6 CS: Signal: 10 V, IEC 61000-4-8 ( Magnetic Field), 30A/m, IEC 61000-4-11 (General Immunity in Industrial Environments) IP Rating: IP40 Protection ACT: TAA, BAA, NDAA |
||
Environmental | REACH, RoHS and WEEE | ||
PoE Modes | IEEE Alternate A (Alt A) 4-Pair |
||
Frame Size | Up to 10,240 bytes | ||
Port Types |
Copper: 10/100/1000BASE-T (RJ-45)
Fiber: 1000BASE-X (ST, SC, LC, SFP)
10/100/1000BASE-T SGMII SFP |
||
Cable Types |
Copper: EIA/TIA 568A/B, Cat 5 UTP and higher
Fiber: Multimode: 50/125, 62.5/125μm
Single-mode: 9/125μm |
||
DC Power Requirements | 60W BT Models: +46 to +57VDC; 4.46A @ 56VDC 2 Pin Terminal (isolated) |
100W BT Models: +46 to +57VDC; 7.31A @ 56VDC 2 Pin Terminal (isolated) |
|
Dimensions (W x D X H) |
1.5” x 5.5” x 5.5” (38.1 mm x 139.7 mm x 139.7 mm) | ||
Weight | 170 lbs.; 772 grams | ||
Operating Temperature | Extended: -40 to 75°C Storage: -40 to 80°C |
||
Humidity | 5% to 95% (non-condensing) | ||
Altitude | -100m to 4,000m (operational) | ||
MTBF (hrs) | 273,000 | ||
Warranty | 5 year product warranty with 24/7/365 free Technical Support |
Description |
IEEE 802.3af 15W PoE |
IEEE 802.3at 30W PoE+ |
IEEE 802.3.bt 60W PoE (Type 3) |
IEEE 802.3bt 100W PoE (Type 4) |
---|---|---|---|---|
Power Supply Voltage Range | 46.0 to 57.0 VDC | 51.0 to 57.0 VDC | 51.0 to 57.0 VDC | 53.0 to 57.0 VDC |
Voltage Range at PSE port Output | 44.0 to 56.0 VDC | 50.0 to 56.0 VDC | 50.0 to 56.0 VDC | 52.0 to 56.0 VDC |
Maximum Power from PoE/PSE port | 15.4 watts | 30 watts | 60 watts | 100 watts |
Minimum Voltage at PoE/PD port input* | 37.0 VDC | 42.5 VDC | 42.5 VDC | 41.1 VDC |
Minimum Power at PoE/PD port* | 12.95 watts | 25.5 watts | 51 watts | 71 watts |
* at 100 meters using Cat5 |
RuggedNet GHPoEBT/Si IEEE 802.3bt 60W Models | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Fiber Type | Distance | Connector Type | Tx/Rx Lambda (nm) | Min. Tx Power (dBm) | Max. Tx Power (dBm) | Min. Rx Power (dBm) | Max. Rx Power (dBm) | Min Atten (dB) | Link Budget (dB) | ||||
ST | SC | LC | SFP | RJ-45 | |||||||||
MM/DF | 220/550m1 | 3200B-0-14-pZ | 3202B-0-14-pZ | 3206B-0-14-pZ | - | - | 850/850 | -10 | -4 | -17 | -3 | - | 7 |
MM/DF (x2) | 220/550m1 | - | - | 3206B-0-24-pZ | - | - | 850/850 | -10 | -4 | -17 | -3 | - | 7 |
MM/DF | 2km | - | 3202B-6-14-pZ | - | - | - | 1310/1310 | -9.5 | -3 | -19.5 | -3 | - | 10 |
SM/DF | 12km | 3201B-1-14-pZ | 3203B-1-14-pZ | 3207B-1-14-pZ | - | - | 1310/1310 | -9.5 | -3 | -19.5 | -3 | - | 10 |
SM/DF (x2) | 12km | - | - | 3207B-1-24-pZ | - | - | 1310/1310 | -9.5 | -3 | -19.5 | -3 | - | 10 |
SM/DF | 34km | - | 3203B-2-14-pZ | - | - | - | 1310/1310 | -5 | 0 | -23 | -3 | 3 | 18 |
SM/DF | 80km | - | 3203B-3-14-pZ | - | - | - | 1550/1550 | -5 | 0 | -23 | -3 | 3 | 18 |
SM/DF | 110km | - | 3203B-4-14-pZ | - | - | - | 1550/1550 | 0 | 5 | -24 | -3 | 8 | 24 |
SM/DF | 140km | - | 3203B-5-14-pZ | - | - | - | 1550/1550 | 2 | 5 | -28 | -8 | 13 | 30 |
MM/SF2 | 220/550m1 | - | 3210B-0-14-pZ | - | - | - | 1310/1550 | -9 | -3 | -18 | -3 | - | 9 |
MM/SF2 | 220/550m1 | - | 3211B-0-14-pZ | - | - | - | 1550/1310 | -9 | -3 | -18 | -3 | - | 9 |
SM/SF2 | 20km |
- | 3210B-1-14-pZ | - | - | - | 1310/1550 | -9.5 | -3 | -20 | -3 | - | 10.5 |
SM/SF2 | 20km |
- | 3211B-1-14-pZ | - | - | - | 1550/1310 | -9.5 | -3 | -20 | -3 | - | 10.5 |
SM/SF2 | 40km |
- | 3210B-2-14-pZ | - | - | - | 1310/1550 | -3 | 0 | -20 | -3 | 3 | 17 |
SM/SF2 | 40km |
- | 3211B-2-14-pZ | - | - | - | 1550/1310 | -3 | 0 | -20 | -3 | 3 | 17 |
SFP (x1) | - | - | - | - | 3219B-0-14-pZ | - | - | - | - | - | - | - | - |
SFP (x2) | - | - | - | - | 3219B-0-24-pZ | - | - | - | - | - | - | - | - |
RJ-45 (x2) | 100m | - | - | - | - | 3219B-1-24-pZ | - | - | - | - | - | - | - |
1 62.5/125µm, 100/140µm multimode fiber up to 220m. 50/125µm multimode fiber up to 550m. 2 When using single-fiber (SF) models, the Tx wavelength on one end has to match the Rx wavelength on the other. MM = Multimode, SM = Single-mode, DF = Dual Fiber, SF = Single-fiber Contact Omnitron for other fiber options. Order the appropriate SFPs separately. Visit the Optical Transceivers web page. |
1 = Single DC 2-Pin Terminal Power Connector |
2 = Dual DC 2-Pin Terminal Power Connectors |
Z = Extended temperature (-40 to 75°C) |
RuggedNet GHPoEBT/Si IEEE 802.3bt 100W Models | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Fiber Type | Distance | Connector Type | Tx/Rx Lambda (nm) | Min. Tx Power (dBm) | Max. Tx Power (dBm) | Min. Rx Power (dBm) | Max. Rx Power (dBm) | Min Atten (dB) | Link Budget (dB) | ||||
ST | SC | LC | SFP | RJ-45 | |||||||||
MM/DF | 220/550m1 | 3240B-0-14-pZ | 3242B-0-14-pZ | 3246B-0-14-pZ | - | - | 850/850 | -10 | -4 | -17 | -3 | - | 7 |
MM/DF (x2) | 220/550m1 | - | - | 3246B-0-24-pZ | - | - | 850/850 | -10 | -4 | -17 | -3 | - | 7 |
MM/DF | 2km | - | 3242B-6-14-pZ | - | - | - | 1310/1310 | -9.5 | -3 | -19.5 | -3 | - | 10 |
SM/DF | 12km | 3241B-1-14-pZ | 3243B-1-14-pZ | 3247B-1-14-pZ | - | - | 1310/1310 | -9.5 | -3 | -19.5 | -3 | - | 10 |
SM/DF (x2) | 12km | - | - | 3247B-1-24-pZ | - | - | 1310/1310 | -9.5 | -3 | -19.5 | -3 | - | 10 |
SM/DF | 34km | - | 3243B-2-14-pZ | - | - | - | 1310/1310 | -5 | 0 | -23 | -3 | 3 | 18 |
SM/DF | 80km | - | 3243B-3-14-pZ | - | - | - | 1550/1550 | -5 | 0 | -23 | -3 | 3 | 18 |
SM/DF | 110km | - | 3243B-4-14-pZ | - | - | - | 1550/1550 | 0 | 5 | -24 | -3 | 8 | 24 |
SM/DF | 140km | - | 3243B-5-14-pZ | - | - | - | 1550/1550 | 2 | 5 | -28 | -8 | 13 | 30 |
MM/SF2 | 220/550m1 | - | 3250B-0-14-pZ | - | - | - | 1310/1550 | -9 | -3 | -18 | -3 | - | 9 |
MM/SF2 | 220/550m1 | - | 3251B-0-14-pZ | - | - | - | 1550/1310 | -9 | -3 | -18 | -3 | - | 9 |
SM/SF2 | 20km |
- | 3251B-1-14-pZ | - | - | - | 1310/1550 | -9.5 | -3 | -20 | -3 | - | 10.5 |
SM/SF2 | 20km |
- | 3251B-1-14-pZ | - | - | - | 1550/1310 | -9.5 | -3 | -20 | -3 | - | 10.5 |
SM/SF2 | 40km |
- | 3251B-2-14-pZ | - | - | - | 1310/1550 | -3 | 0 | -20 | -3 | 3 | 17 |
SM/SF2 | 40km |
- | 3251B-2-14-pZ | - | - | - | 1550/1310 | -3 | 0 | -20 | -3 | 3 | 17 |
SFP (x1) | - | - | - | - | 3259B-0-14-pZ | - | - | - | - | - | - | - | - |
SFP (x2) | - | - | - | - | 3259B-0-24-pZ | - | - | - | - | - | - | - | - |
RJ-45 (x2) | 100m | - | - | - | - | 3259B-1-24-pZ | - | - | - | - | - | - | - |
1 62.5/125µm, 100/140µm multimode fiber up to 220m. 50/125µm multimode fiber up to 550m. 2 When using single-fiber (SF) models, the Tx wavelength on one end has to match the Rx wavelength on the other. MM = Multimode, SM = Single-mode, DF = Dual Fiber, SF = Single-fiber Contact Omnitron for other fiber options. Order the appropriate SFPs separately. Visit the Optical Transceivers web page. |
1 = Single DC 2-Pin Terminal Power Connector |
2 = Dual DC 2-Pin Terminal Power Connectors |
Z = Extended temperature (-40 to 75°C) |
Model Number | Description | |
---|---|---|
8260-3 | Wall Mounting Plate | |
8260-0 | 19" rack mount shelf |
Model | Product Operating Temperature Range | Watts Required | Industrial Power Supply Model and Operating Temperature Range | |
---|---|---|---|---|
-25 to 70C | -30 to 70C | |||
GHPoEBT/Si 60W | Commercial / Wide / Extended | 250 watts | 9170-PS-480 | - |
GHPoEBT/Si 100W | Commercial / Wide | 410 watts | 9170-PS-480 | - |
GHPoEBT/Si 100W | Extended | 410 watts | - | 9170-PS-960 |
RuggedNet GHPoEBT/Si (Data Sheet)
RuggedNet GHPoEBT/Si (User Manual)
Wall Mount Plate (User Manual)
9170-PS-480-Industrial-Power-Supply
9170-PS-960-Industrial-Power-Supply
3200B-0-14-1Z, 3200B-0-14-2Z, 3201B-1-14-1Z, 3201B-1-14-2Z, 3202B-0-14-1Z, 3202B-0-14-2Z, 3202B-6-14-1Z, 3202B-6-14-2Z, 3203B-1-14-1Z, 3203B-1-14-2Z, 3203B-2-14-1Z, 3203B-2-14-2Z, 3203B-3-14-1Z, 3203B-3-14-2Z, 3203B-4-14-1Z, 3203B-4-14-2Z, 3203B-5-14-1Z, 3203B-5-14-2Z, 3206B-0-14-1Z, 3206B-0-14-2Z, 3206B-0-24-1Z, 3206B-0-24-2Z, 3207B-1-14-1Z, 3207B-1-14-2Z, 3207B-1-24-1Z, 3207B-1-24-2Z, 3210B-0-14-1Z, 3210B-0-14-2Z, 3211B-0-14-1Z, 3211B-0-14-2Z, 3210B-1-14-1Z, 3210B-1-14-2Z, 3211B-1-14-1Z, 3211B-1-14-2Z, 3210B-2-14-1Z, 3210B-2-14-2Z, 3211B-2-14-1Z, 3211B-2-14-2Z, 3219B-0-14-1Z, 3219B-0-14-2Z, 3219B-0-24-1Z, 3219B-1-24-1Z, 3219B-0-24-2Z, 3219B-1-24-2Z, 3240B-0-14-1Z, 3240B-0-14-2Z, 3241B-1-14-1Z, 3241B-1-14-2Z, 3242B-0-14-1Z, 3242B-0-14-2Z, 3242B-6-14-1Z, 3242B-6-14-2Z, 3243B-1-14-1Z, 3243B-1-14-2Z, 3243B-2-14-1Z, 3243B-2-14-2Z, 3243B-3-14-1Z, 3243B-3-14-2Z, 3243B-4-14-1Z, 3243B-4-14-2Z, 3243B-5-14-1Z, 3243B-5-14-2Z, 3246B-0-14-1Z, 3246B-0-14-2Z, 3246B-0-24-1Z, 3246B-0-24-2Z, 3247B-1-14-1Z, 3247B-1-14-2Z, 3247B-1-24-1Z, 3247B-1-24-2Z, 3250B-0-14-1Z, 3250B-0-14-2Z, 3251B-0-14-1Z, 3251B-0-14-2Z, 3250B-1-14-1Z, 3250B-1-14-2Z, 3251B-1-14-1Z, 3251B-1-14-2Z, 3250B-2-14-1Z, 3250B-2-14-2Z, 3251B-2-14-1Z, 3251B-2-14-2Z, 3259B-0-14-1Z, 3259B-0-14-2Z, 3259B-0-24-1Z, 3259B-1-24-1Z, 3259B-0-24-2Z, 3259B-1-24-2Z,