The OmniConverter FPoE+/S are multi-port IEEE 802.3at PoE+ Ethernet media converters that feature one or two uplink ports and one or two 10/100 RJ-45 PoE+ user ports.
The FPoE+/S provides up to 30W PoE+ per RJ-45 user port and supports frame sizes up to 10,240 bytes. The uplink ports can be fixed fiber or SFP receptacle or 10/100 RJ-45 copper.
The OmniConverter FPoE+/S supports Directed Switch mode, which directs multicast traffic (such as video) only to the appropriate uplink port, preventing the multicast video traffic from flooding other network ports.
Models with two fiber port support redundant fiber uplinks for critical applications that require protection and restoration in the event of a fiber failure. The second fiber port can also be used to cascade multiple media converters.
Models with two fiber ports also support Dual Device mode that enables the module to operate as two independent and isolated media converters. In Dual Device mode, the FPoE+/S provides separate and independent data traffic paths between the two uplink ports and two user ports.
Configurable features include link modes and a PoE power reset function that enables the attached PD device, such as a camera or access point, to be re-initialized remotely, eliminating the need for costly truck rolls to remote PD sites. When a problem with a PD is detected, the fiber port on the module can be disconnected, triggering the PoE power reset function.
Link modes can be configured to propagate loss-oflink faults to managed devices, immediately notifying administrators of network outages.
The FPoE+/S supports fixed fiber connectors or Small Form Pluggable (SFP) transceiver receptacles, enabling easy adaptability to different fiber types, distances and wavelengths. SFP models support 100Mbps standard, CWDM and DWDM transceivers in a variety of distances and fiber types.
The FPoE+/S can be tabletop mounted, wall mounted, or DIN-rail mounted using an optional DIN-rail mounting kit. They can also be mounted on a 1U 19” rack-mount shelf. They are available with DC input power via terminal connectors or an external 100 to 240V AC power adapters.
Dual Device Mode Application
This Dual Device feature is extremely useful when two isolated networks domains share a single network distribution location.
The example below depicts a scenario where a surveillance security (green) network and a Wi-Fi (purple) network are sharing a single hub distribution location. Using the two uplinks and the Dual Switch mode facilitates using a single PoE media converter driving both the Cameras and the Wi-Fi Access Points while maintaining isolation between the networks.
Daisy Chain Application
This example demonstrates the daisy chain capabilities of the OmniConverter media converters. In this application each media converter connects to its neighboring converter via its uplink ports. The daisy chain can continue to additional converter using this method of connectivity.
Each OmniConverter media converter provides connectivity to the fiber links, and power to IP cameras and Wi-Fi access points at each location along the daisy chain.
Description | OmniConverter FPoE+/S 10/100BASE-T to 100BASE-X Fiber Media Converter with PoE+ |
||
---|---|---|---|
Standard Compliances |
IEEE 802.3, IEEE 802.3af (15.40 watts), IEEE 802.3at (30 watts) |
||
Regulatory Compliances (Pending) |
Safety: UL 62368-1, UL 60950-1, IEC 62368-1, IEC 60950-1, EN 62368-1, EN 60950-1, CAN/CSA C22.2 No. 62368-1-14, CAN/CSA C22.2 No. 60950-1, CE Mark, UKCA EMC: EN 55032/24 CE Emissions/Immunity, IEC 61000-6-4 Industrial Emissions, IEC 61000-6-2 Industrial Immunity EMI: CISPR 32, FCC 47 Part 15 Subpart B Class A EMS: IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV, IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m, IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV (DC models), IEC 61000-4-4 EFT: Power: 1 kV; Signal: 1 kV (AC models), IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV (DC models), IEC 61000-4-5 Surge: Power: 1 kV Line/Line; 2 kV Line/Gnd; Signal: 2 kV (AC models), IEC 61000-4-6 CS: Signal: 10 V, IEC 61000-4-8 (Magnetic Field) 30A/m, IEC 61000-4-11 (Voltage Dips, interrupts) IP Rating: IP30D Protection ACT: TAA, BAA,NDAA |
||
Environmental | REACH, RoHS and WEEE | ||
PoE Power Modes | IEEE Alterative A (Alt A) | ||
Frame Size | Up to 10,240 bytes | ||
Port Types |
Copper: 10/100BASE-T (RJ-45) Fiber: 100BASE-X (ST, SC, SFP) |
||
Cable Types |
Copper: EIA/TIA 568A/B, Cat 5 UTP and higher Fiber: Multimode: 50/125, 62.5/125µm Single-mode: 9/125µm |
||
AC Power Requirements (Models with AC/DC Adapters) |
1 RJ-45 Port: 100 - 240VAC/50 to 60Hz, 0.33A @ 120VAC (typical) |
2 RJ-45 Ports: 100 - 240VAC/50 - 60Hz, 0.62A @ 120VAC (typical) |
|
DC Power Requirements (Models with DC Terminals) |
1 RJ-45 Port: +/-46 to +/-57VDC, 0.78A @ 56VDC 2 Pin Terminal (isolated) |
2 RJ-45 Ports: +/-46 to +/-57VDC, 1.45A @ 56VDC 2 Pin Terminal (isolated) |
|
A minimum DC input voltage of 50VDC is required to guarantee 25.5 watts (802.3at) at the end of 100 meters of Cat 5 or better | |||
Dimensions (W x D X H) | 3.8” x 4.8” x 1.0” (96.5 mm x 121.9 mm x 25.4 mm) | ||
Weight |
Module Only: 1.0 lbs. (453.6 grams) Module w/ Adapter: 1.9 lbs. (852.6 grams) |
||
Operating Temperature
(See Temperature Derating Table)
|
Commercial: 0 to 50°C
Wide: -40 to 60°C (-20°C AC cold start)
Extended: -40 to 75°C (-20°C AC cold start) Storage: -40 to 80°C |
||
Humidity | 5 to 95% (non-condensing) | ||
Altitude | -100m to 4,000m | ||
MTBF (hrs) | Module: 584,000 AC/DC Adapter: 100,000 |
||
Warranty | Lifetime warranty with 24/7/365 free Technical Support |
Description | IEEE 802.3af PoE | IEEE 802.3at PoE+ |
---|---|---|
Power Supply Voltage Range | 46.0 to 57.0 VDC | 51.0 to 57.0 VDC |
Voltage Range at PSE port Output | 44.0 to 56.0 VDC | 50.0 to 56.0 VDC |
Maximum Power from PoE/PSE port | 15.4 watts | 30 watts |
Minimum Voltage at PoE/PD port input* | 37.0 VDC | 42.5 VDC |
Minimum Power at PoE/PD port* | 12.95 watts | 25.5 watts |
Fiber Type | Distance | Connector Type |
Tx /Rx Lambda (nm) |
Min. Tx Power (dBm) |
Max. Tx Power (dBm) |
Min. Rx Power (dBm) |
Max. Rx Power (dBm) |
Min Attenuation (dB) |
Link Budget (dB) | ||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ST | SC | SFP | RJ-45 | ||||||||||
MM/DF | 5km | 9320N-0-ypt | 9322N-0-ypt | - | - | 1310/1310 | -24 | -14 | -31 | -14 | - | 7 | |
SM/DF | 30km | 9321N-1-ypt | 9323N-1-ypt | - | - | 1310/1310 | -15 | -8 | -31 | -8 | - | 16 | |
SM/DF | 60km | 9321N-2-ypt | 9323N-2-ypt | - | - | 1310/1310 | -5 | 0 | -31 | -3 | 3 | 26 | |
SM/DF | 120km | - | 9323N-3-ypt | - | - | 1550/1550 | -5 | 0 | -31 | -3 | 3 | 26 | |
MM/SF1 | 5km | - | 9330N-0-ypt | - | - | 1310/1550 | -8 | 0 | -28 | 0 | - | 20 | |
MM/SF1 | 5km | - | 9331N-0-ypt | - | - | 1550/1310 | -8 | 0 | -28 | 0 | - | 20 | |
SM/SF1 | 20km | - | 9330N-1-ypt | - | - | 1310/1550 | -15 | -5 | -30 | -3 | - | 15 | |
SM/SF1 | 20km | - | 9331N-1-ypt | - | - | 1550/1310 | -15 | -5 | -30 | -3 | - | 15 | |
SM/SF1 | 40km | - | 9330N-2-ypt | - | - | 1310/1550 | -8 | 0 | -30 | -3 | 3 | 22 | |
SM/SF1 | 40km | - | 9331N-2-ypt | - | - | 1550/1310 | -8 | 0 | -30 | -3 | 3 | 22 | |
RJ-45 (x1) | 100m | - | - | - | 9338N-0-ypt | - | - | - | - | - | - | - | |
RJ-45 (x2) | 100m | - | - | - | 9338N-1-ypt | - | - | - | - | - | - | - | |
SFP (x1) | - | - | - | 9339N-0-ypt | - | - | - | - | - | - | - | - | |
SFP (x2) | - | - | - | 9339N-1-ypt | - | - | - | - | - | - | - | - | |
1 When using single-fiber (SF) models, the Tx wavelength on one end has to match the Rx wavelength on the other. MM = Multimode, SM = Single-mode, DF = Dual Fiber, SF = Single-fiber. Contact Omnitron for other fiber options. Order the appropriate SFPs separately. Visit the Optical Transceivers web page. Contact Omnitron for conformal coating options. |
1 = One RJ-45 Ports |
2 = Two RJ-45 Ports |
1 = External AC/DC Adapter, 100 - 240 VAC included, with US Power Cord |
2 = External AC/DC Adapter, 100 - 240 VAC included, No Power Cord |
8 = External AC/DC Adapter, 100 - 240 VAC included, PS JET/PSE Certified, with Japanese Power Cord |
9 = Direct DC 2 pin terminal connector, no AC/DC power adapter |
<leave blank> = Commercial temperature (0 to 50°C) |
W = Wide temperature (-40 to 60°C) |
Z = Extended temperature (-40 to 75°C) - Check the Derating Table for available wattage for models with AC/DC Power Adapter |
AC/DC Adapter Temperature Derating
Total Available Wattage to RJ-45 Ports
| |||||||
---|---|---|---|---|---|---|---|
Model | RJ-45 Ports | Watts Required |
Watts Available @40°C |
Watts Available @50°C |
Watts Available @60°C |
Watts Available @70°C |
Watts Available @75°C |
FPoE+/S | 1 | 30 watts | Full Power | Full Power | Full Power | Full Power | Full Power |
2 | 60 watts | Full Power | Full Power | Full Power | Full Power | 50 watts | |
The AC/DC Adapter Temperature derating table is not applicable to models with DC Terminal (see Ordering table for Direct DC power option 9). The DC Terminal models will provide full PoE power over the operating temperature range of the module as long as the DC input voltage meets the requirements stated in the specification table.
|
Model Number
|
Description
|
---|---|
8250-0
|
DIN-Rail Mounting Bracket
|
8251-0
|
DIN-Rail Mounting Clip
|
8260-0
|
19" rack mount shelf
|
Previous/Old Base Model # | Previous/Old Model | Enhanced Base Model # | Enhanced Model |
---|---|---|---|
9300 | FPoE/S 15 W per RJ-45 User Port | 9320N | FPoE+/S 30 W per RJ-45 User Port |
9320 | FPoE+/S 30 W per RJ-45 User Port |
Features |
Previous/Old Model FPoE/S and FPoE+/S |
Enhanced Model FPoE+/S | Benefits |
---|---|---|---|
Copper Uplink Ports | N/A | One or two ports | Product flexibility |
Dimensions (W x D x H) |
4.5” x 6.0” x 1.0” |
3.8” x 4.8” x 1.0” | Compact size |
PoE Power Level |
IEEE 802.3af - FPoE/S IEEE 802.3af/at - FPoE+/S |
IEEE 802.3af/at |
15W and 30W versions in one model |
Dual Device Mode | N/A | Models with dual uplink ports | Two independent and isolated Ethernet media converters |
Directed Switch Mode | N/A | ✓ | Prevents multicast (video) traffic from flooding other network ports |
Legacy pre-IEEE Power Standards | ✓ | Alternative A Power Mode | No configuration for the user |
IP Protection | IP20 | IP30D | Provides increased enclosure protection |