RuggedNet® 10GPoE+/Mi

Managed Industrial 6 and 10 Port PoE/PoE+ 10Gigabit Ethernet Switch



Features


  • Managed Industrial 1/10G PoE/PoE+ Ethernet Switch with dual DC powerTwo 1/10G SFP/SFP+ transceiver uplink ports
  • Supports copper and fiber SFP transceivers
  • Supports 10M, 100M, 1G and 10Gbps copper SFP/SFP+ transceivers
  • Four or eight 10/100/1000 copper PoE user ports
  • Jumbo frames up to 10,240 bytes
  • Heartbeat signal to verify connectivity to the PD
  • Configurable PoE Power Reset
  • PoE power management with LLDP MED and MDI TLV, and PoE Power Multi-Day Scheduler
  • Management via Web, Telnet, SSH, SNMPv1/v2c/v3 and serial interfaces
  • Easy to use Hierarchical Command Line Interface
  • SNMP management via Omnitron’s NetOutlook® management software, or third-party SNMP software
  • Supports IPv4 and IPv6
  • IEEE 802.1x, RADIUS, TACACS+ and ACL
  • Email Notification
  • Dual Device mode for operating as two separate switches
  • Directed Switch mode AKA Camera mode to prevent port flooding
  • Alarm contacts and sensors
  • Wall, Rack and DIN-rail mountable
  • Industrial (-40 to 75º C) operating temperature
  • TAA, BAA and NDAA compliant, and Made in the USA
  • Free 24/7/365 Technical Support

ADDITIONAL FEATURES

  • Rapid and Multiple Spanning Tree Protocol
  • IEC 62439-2 Industrial Ring Media Redundancy
  • IEEE 802.1ax LAG and LACP; Active/Active and Active/Standby
  • IPv4 Internet Group Management (IGMP) and IPv6 Multicast Listener Discovery (MLD) snooping
  • DHCP Relay Option 82, DHCPv6 and DHCPv6 Relay
  • IEEE 802.1ab Link Layer Discovery Protocol
  • Rate Limiting, Queue prioritization and Class of Service
  • IEEE 802.1Q VLAN tagging and IEEE 802.1ad Q-in-Q
  • Static MAC configuration and blocking of unknown Unicast/Multicast addresses
  • Port Access Control for enhanced security
  • Broadcast / Multicast / Unicast Storm Prevention
  • SNTP / NTP and time of day




Description


The RuggedNet 10GPoE+/Mi is a ruggedized managed PoE and PoE+ industrial Ethernet switch that features two 1/10G uplink ports and four or eight 10/100/1000 RJ-45 PoE/PoE+ user ports.

The RuggedNet 10GPoE+/Mi is a Layer 2 Ethernet switch that forwards frames to any port based on their MAC address.

All models support Directed Switch mode, which directs multicast traffic (such as video) only to the appropriate uplink port, preventing multicast traffic from flooding other network ports.

The switches support redundant uplinks, industrial ring Media Redundancy Protocol (MRP), Spanning Tree protocol and daisy-chain configurations for high availability industrial network applications.

The switches support Dual Device mode that enables the 10GPoE+/Mi to operate as two independent and isolated Ethernet switches.

The mode of operation can be configured using easily accessible DIP-switches or using Web, Telnet, SSH, SNMPv1/v2c/v3 or Serial Console management interfaces. IPv4 and IPv6 are supported on the switches. These management interfaces provide access to filtering and security options, such as, broadcast storm prevention, IGMP, IEEE 802.1x, RADIUS, TACACS+ and Access Control Lists. Email notification and alarm reporting is provided.

The RuggedNet PoE switches are available with Small Form Pluggable (SFP) transceiver receptacle ports. The SFP ports support 10/100/1000BASE-T, 1000BASE-T and 10GBASE-T copper transceivers. They also support 1G and 10G multimode or single-mode fiber, dual or singlefiber and standard, CWDM and DWDM wavelengths.

The switches feature a Remote PoE Power Reset function that enables the user to remotely power-cycle and reset each PD. They also feature a configurable Heartbeat Reset function that automatically pings the attached PDs and automatically power cycles and resets the PDs when detecting a heartbeat loss.

An alarm relay is available to detect user configured events. The relay contact can be configured for normally open or normally closed operation. One alarm input is available for detecting external events such as door open or closed.

All models can be wall or rack mounted using a wall mount bracket and shelf or DIN-rail mounted using the included DIN-rail mounting clip. They are available with dual DC input power.





Examples


Daisy-Chain and Ring Topology Network Application

This example demonstrates the daisy chaining and ring capabilities of the RuggedNet. In this application each RuggedNet switch connects to its neighboring switches via its uplink ports eventually closing the ring.

Using this network architecture combined with ring protection protocols such as Media Redundancy Protocol (MRP) or Rapid Spanning Tree Protocol (RSTP) facilitates a highly resilient network required in mission critical applications.

Industrial Manufactring Application 9582 10 gpo M

Dual Device Mode Application

This Dual Device feature is extremely useful when two isolated networks domains share a single network distribution location.

The example below depicts a scenario where a surveillance security (purple) network and a Wi-Fi (green) network are sharing a single hub distribution location. Using the two uplinks and the Dual Switch mode facilitates using a single PoE switch driving both the Cameras and the Wi-Fi Access Points while maintaining isolation between the networks.

Dual Media Converter Mode 9582 10 gpo Mi





Specifications


Description RuggedNet 10GPoE+/Mi
10/100/1000BASE-T with 1/10G Uplink Ports
Ruggedized Managed PoE+ 10Gigabit Ethernet Switch
Standard Compliances

IEEE 802.3, IEEE 802.1Q, IEEE 802.1ad, IEEE 802.1ab, IEEE 802.1ax, IEEE 802.1w RSTP/MSTP

RFC 5424, RFC 4541, RFC 2710, IEC 624339-2,

SMTP, SNTP, RADIUS, TACACS+, IEEE 802.1x

IEEE 802.3af (15.40 watts max) and IEEE 802.3at (30 watts max)

Regulatory Compliances
(*Pending)

Safety*: UL 62368-1, UL 60950-1,

              IEC 62368-1, IEC 60950-1,

              EN 62368-1, EN 60950-1,

              CAN/CSA C22.2 No. 62368-1-14, CAN/CSA C22.2 No. 60950-1,

              CE Mark,

              UKCA

EMC:     EN 55032/24 CE Emissions/Immunity,

              IEC 61000-6-4 Industrial Emissions, IEC 61000-6-2 Industrial Immunity

EMI:      CISPR 32,

              FCC 47 Part 15 Subpart B Class A

EMS:     IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV,

              IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m (on UTP cabling) and 20 V/m (on STP cabling)

              IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV,

              IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV, IEC 61000-4-6 CS: Signal: 10 V,

              IEC 61000-4-8 ( Magnetic Field), 30A/m, IEC 61000-4-11 (General Immunity in Industrial Environments)

IP Rating: IP40 Protection

ACT: TAA, BAA, NDAA

Environmental REACH, RoHS and WEEE
Management

IPv4 and IPv6 address

Web, Telnet, SSH, SNMPv1/v2c/v3

In-Band management via Ethernet port

Out-of-band management via serial port

PoE Modes IEEE Alternate A (Alt A)
Frame Size Up to 10,240 bytes
Port Types

Copper:      10/100/1000BASE-T (RJ-45)

SFP/SFP+: 10GBASE-X Fiber Transceivers

                   10GBASE-T Copper Transceivers

                   1000BASE-X Fiber Transceivers

                   1000BASE-T Copper Transceivers

                   10/100/1000BASE-T SGMII Copper Transceivers

Serial:         RJ-45

Cable Types

Copper: EIA/TIA 568A/B, Cat 5 UTP and higher

Fiber:   Multimode: 50/125, 62.5/125µm

            Single-mode: 9/125µm

Serial: Category 3 and higher

DC Power Requirements

4 RJ-45 Ports:

+46 to +57VDC;

2.33A @ 56VDC

2 Pin Terminal (isolated)

8 RJ-45 Ports

+46 to +57VDC;

4.49A @ 56VDC

2 Pin Terminal (isolated)

Alarm Contact (Output)

2 form C Relay for Normally Open and Normally Closed Operation

110VDC/125VAC Maximum Voltage

2A Maximum Current

Alarm Sensor (Input) 2.0ma @ 3.3VDC Closure Detection
Dimensions (W x D x H) 1.5” x 5.5” x 5.5” (38.1 mm x 139.7 mm x 139.7 mm)
Weight

4 RJ-45 Ports:

1.70 lb. (772 grams)

8 RJ-45 Ports:

1.77 lb. (803 grams)

Operating Temperature Extended: -40 to 75°C
Storage: -40 to 80°C
Humidity 5% to 95% (non-condensing)
Altitude -100m to 4,000m (operational)
MTBF (hrs) 263,000
Warranty
5 year product warranty with 24/7/365 free Technical Support

 

Power / Voltage Requirements and Specifications
Description

IEEE 802.3af PoE

IEEE 802.3at PoE+

Power Supply Voltage Range 46.0 to 57.0 VDC 51.0 to 57.0 VDC
Voltage Range at PSE port Output 44.0 to 56.0 VDC 50.0 to 56.0 VDC
Maximum Power from PoE/PSE port 15.4 watts 30 watts
Minimum Voltage at PoE/PD port input* 37.0 VDC 42.5 VDC
Minimum Power at PoE/PD port* 12.95 watts 25.5 watts
* at 100 meters using Cat5




Ordering


RuggedNet 10GPoE+/Mi Models
Model NumberDescription
9582-0-24-2Z RuggedNet 10GPoE+/Mi 2 x SFP/SFP+ uplink port and 4 x RJ-45 PoE/PoE+ ports, Dual DC Terminal Connectors, Industrial Temperature
9582-0-28-2Z RuggedNet 10GPoE+/Mi 2 x SFP/SFP+ uplink port and 8 x RJ-45 PoE/PoE+ ports, Dual DC Terminal Connectors, Industrial Temperature
Contact Omnitron for other fiber options. Order the appropriate SFPs separately. Visit the Omnitron Optical Transceivers web page. web page.

 

Accessories
Model NumberDescription Wall Mount Plate 
 8260-3  Wall Mounting Plate
 8260-0  19" rack mount shelf