Main Menu
Useful Links
Contact us
Follow us
© 2024 Omnitron Systems Technology, Inc. All Rights Reserved. | Privacy Policy
ADDITIONAL FEATURES
The RuggedNet G/Mi is a ruggedized Industrial gigabit Ethernet switch that features fiber or copper uplink ports and four or eight 10/100/1000 RJ-45 copper user ports. The RuggedNet G/Mi enables industrial network distance extension with fiber or copper cabling.
The RuggedNet G/Mi is a standard Layer 2 Ethernet switch that forwards frames to any port based on their MAC address.
The RuggedNet G/Mi supports Directed Switch mode, which directs multicast traffic (such as video) only to the appropriate uplink port, preventing the multicast video traffic from flooding other network ports.
Models with two fiber or two copper uplink ports support redundant uplinks, industrial ring Media Redundancy Protocol (MRP), Spanning Tree protocol and daisy-chain configurations for high availability industrial network applications.
Models with two fiber or two copper uplink ports also support Dual Device mode that enables the G/Mi to operate as two independent and isolated Ethernet switches. In Dual Device mode, the G/Mi provides separate and independent data traffic paths between the two uplink ports and four or eight user ports.
The mode of operation can be configured using easily accessible DIP-switches or using Web, Telnet, SSH, SNMPv1/v2c/v3 or Serial Console management interfaces. IPv4 and IPv6 are supported on the switches. These management interfaces provide access to filtering and security options, such as, broadcast storm prevention, IGMP, IEEE 802.1x, RADIUS, TACACS+ and Access Control Lists. Email notification and alarm reporting is provided.
Models are available with fixed ST, SC, and LC fiber connectors or Small Form Pluggable (SFP) transceiver receptacles. Fiber ports support multimode or single-mode and dual fiber or single-fiber with distances up to 140km. SFP models support a variety of distances in standard, CWDM and DWDM wavelengths.
All models can be wall or rack mounted using a wall mount bracket and shelf or DIN-rail mounted using the included DIN-rail mounting clip. They are available with single or dual DC input power options.
An alarm relay is available to detect user configured events. The relay contact can be configured for normally open or normally closed operation. One alarm input is available for detecting external events such as door open or closed.
Dual Device Mode Application
This Dual Device feature is extremely useful when two isolated networks domains share a single network distribution location.
The example below depicts a scenario where the Quality Control (green) network and the Manufacturing (purple) network are sharing a single hub distribution location. Using the two uplinks and the Dual Switch mode facilitates using a single switch driving both the Quality Control and the Manufacturing devices while maintaining isolation between the networks.
Daisy-Chain and Ring Topology Network Application
This example demonstrates the daisy chaining and ring capabilities of the RuggedNet. In this application each RuggedNet switch connects to its neighboring switches via its uplink ports eventually closing the ring. The RuggedNet switches are providing connectivity between the workstations and the router.
Using this network architecture combined with ring protection protocols such as Media Redundancy Protocol (MRP) or Rapid Spanning Tree Protocol (RSTP) facilitates a highly resilient network required in mission critical applications.
Description | RuggedNet® G/Mi 10/100/1000BASE-T with Gigabit Fiber or 10/100/1000BASE-T Copper Uplinks Industrial Managed 6 and 10 Port Gigabit Ethernet Switch |
|
---|---|---|
Standard Compliances |
IEEE 802.3, IEEE 802.1Q, IEEE 802.1ad, IEEE 802.1ab, IEEE 802.1ax, IEEE 802.1w RSTP/MSTP RFC 5424, RFC 4541, RFC 2710, IEC 624339-2, SMTP, SNTP, RADIUS, TACACS+, IEEE 802.1 |
|
Regulatory Compliances |
Safety: UL 62368-1, UL 60950-1, IEC 62368-1, IEC 60950-1, EN 62368-1, EN 60950-1, CAN/CSA C22.2 No. 62368-1-14, CAN/CSA C22.2 No. 60950-1, CE Mark, UKCA EMC: EN 55032/24 CE Emissions/Immunity, IEC 61000-6-4 Industrial Emissions, IEC 61000-6-2 Industrial Immunity EMI: CISPR 32, FCC 47 Part 15 Subpart B Class A EMS: IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV, IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m (on UTP cabling) and 20 V/m (on STP cabling) IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV, IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV, IEC 61000-4-6 CS: Signal: 10 V, IEC 61000-4-8 ( Magnetic Field), 30A/m, IEC 61000-4-11 (General Immunity in Industrial Environments) IP Rating: IP40 Protection ACT: TAA, BAA, NDAA |
|
Environmental | REACH, RoHS and WEEE | |
Management |
Pv4 and IPv6 address Web, Telnet, SSH, SNMPv1/v2c/v3 In-Band management via Ethernet port Out-of-band management via serial port |
|
Frame Size | Up to 10,240 bytes | |
Port Types | Copper: 10/100/1000BASE-T (RJ-45) Fiber: 1000BASE-X (ST, SC, LC, SFP) 10/100/1000BASE-T SGMII (SFP) Serial: RJ-45 |
|
Cable Types |
Copper: EIA/TIA 568A/B, Cat 5 UTP and higher
Fiber: Multimode: 50/125, 62.5/125μm Single-mode: 9/125μm Serial: Category 3 and higher |
|
DC Power Requirements | 4 RJ-45 Ports: +12 to +57VDC; 0.68A @ 12VDC 0.17A @ 48VDC 2 Pin Terminal (isolated) |
8 RJ-45 Ports: +12 to +57VDC; 0.75A @ 12VDC 0.19A @ 48VDC 2 Pin Terminal (isolated) |
Alarm Contact (Output) |
2 form C Relay for Normally Open and Normally Closed Operation 110VDC/125VAC Maximum Voltage 2A Maximum Current |
|
Alarm Sensor (Input) | 2.0ma @ 3.3VDC Closure Detection | |
Dimensions (W x D x H) |
1.5” x 5.5” x 5.5” (38.1 mm x 139.7 mm x 139.7 mm) | |
Weight | 4 RJ-45 Ports: 1.70 lb.; 772 grams |
8 RJ-45 Ports: 1.77 lb.; 803 grams |
Operating Temperature | -40 to 75°C | |
Humidity | 5% to 95% (non-condensing) | |
Altitude | -100m to 4,000m (operational) | |
MTBF (hrs) | 282,000 | |
Warranty |
5 year product warranty with 24/7/365 free Technical Support
|
RuggedNet G/Mi Models | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Fiber Type | Distance | Connector Type | Tx/Rx Lambda (nm) | Min. Tx Power (dBm) | Max. Tx Power (dBm) | Min. Rx Power (dBm) | Max. Rx Power (dBm) | Min Atten (dB) | Link Budget (dB) | ||||
ST | SC | LC | SFP | RJ-45 | |||||||||
MM/DF | 220/550m1 | 2840-0-1y-pZ | 2842-0-1y-pZ | 2846-0-1y-pZ | - | - | 850/850 | -10 | -4 | -17 | -3 | - | 7 |
MM/DF (x2) | 220/550m1 | - | - | 2846-0-2y-pZ | - | - | 850/850 | -10 | -4 | -17 | -3 | - | 7 |
MM/DF | 2km | - | 2842-6-1y-pZ | - | - | - | 1310/1310 | -9.5 | -3 | -19.5 | -3 | - | 10 |
SM/DF | 12km | 2841-1-1y-pZ | 2843-1-1y-pZ | 2847-1-1y-pZ | - | - | 1310/1310 | -9.5 | -3 | -19.5 | -3 | - | 10 |
SM/DF (x2) | 12km | - | - | 2847-1-2y-pZ | - | - | 1310/1310 | -9.5 | -3 | -19.5 | -3 | - | 10 |
SM/DF | 34km | - | 2843-2-1y-pZ | - | - | - | 1310/1310 | -5 | 0 | -23 | -3 | 3 | 18 |
SM/DF | 80km | - | 2843-3-1y-pZ | - | - | - | 1550/1550 | -5 | 0 | -23 | -3 | 3 | 18 |
SM/DF | 110km | - | 2843-4-1y-pZ | - | - | - | 1550/1550 | 0 | 5 | -24 | -3 | 8 | 24 |
SM/DF | 140km | - | 2843-5-1y-pZ | - | - | - | 1550/1550 | 2 | 5 | -28 | -8 | 13 | 30 |
MM/SF2 | 220/550m1 | - | 2850-0-1y-pZ | - | - | - | 1310/1550 | -9 | -3 | -18 | -3 | - | 9 |
MM/SF2 | 220/550m1 | - | 2851-0-1y-pZ | - | - | - | 1550/1310 | -9 | -3 | -18 | -3 | - | 9 |
SM/SF2 | 20km |
- | 2850-1-1y-pZ | - | - | - | 1310/1550 | -9.5 | -3 | -20 | -3 | - | 10.5 |
SM/SF2 | 20km |
- | 2851-1-1y-pZ | - | - | - | 1550/1310 | -9.5 | -3 | -20 | -3 | - | 10.5 |
SM/SF2 | 40km |
- | 2850-2-1y-pZ | - | - | - | 1310/1550 | -3 | 0 | -20 | -3 | 3 | 17 |
SM/SF2 | 40km |
- | 2851-2-1y-pZ | - | - | - | 1550/1310 | -3 | 0 | -20 | -3 | 3 | 17 |
SFP (x1) | - | - | - | - | 2859-0-1y-pZ | - | - | - | - | - | - | - | - |
SFP (x2) | - | - | - | - | 2859-0-2y-pZ | - | - | - | - | - | - | - | - |
RJ-45 (x2) | 100m | - | - | - | - | 2859-1-2y-pZ | - | - | - | - | - | - | - |
1 62.5/125µm, 100/140µm multimode fiber up to 220m. 50/125µm multimode fiber up to 550m. 2 When using single-fiber (SF) models, the Tx wavelength on one end has to match the Rx wavelength on the other. MM = Multimode, SM = Single-mode, DF = Dual Fiber, SF = Single-fiber Contact Omnitron for other fiber options. Order the appropriate SFPs separately. Visit the Optical Transceivers web page. |
4 = Four RJ-45 Ports |
8 = Eight RJ-45 Ports |
1 = Single DC 2-Pin Terminal Power Connector |
2 = Dual DC 2-Pin Terminal Power Connectors |
Z = Extended temperature (-40 to 75°C) |
Model Number | Description | |
---|---|---|
8260-3 | Wall Mounting Plate | |
8260-0 | 19" rack mount shelf |
RuggedNet Command Line Interface (User Manual)
RuggedNet Web Interface (User Manual)
OmniConverter / RuggedNet 2.5 Hierarchical CLI (User Manual)
Wall Mount Plate (User Manual)
2840-0-14-1Z, 2840-0-14-2Z, 2841-1-14-1Z, 2841-1-14-2Z, 2842-0-14-1Z, 2842-0-14-2Z, 2842-6-14-1Z, 2842-6-14-2Z, 2843-1-14-1Z, 2843-1-14-2Z, 2843-2-14-1Z, 2843-2-14-2Z, 2843-3-14-1Z, 2843-3-14-2Z, 2843-4-14-1Z, 2843-4-14-2Z, 2843-5-14-1Z, 2843-5-14-2Z, 2846-0-14-1Z, 2846-0-14-2Z, 2846-0-24-1Z, 2846-0-24-2Z, 2847-1-14-1Z, 2847-1-14-2Z, 2847-1-24-1Z, 2847-1-24-2Z, 2850-0-14-1Z, 2850-0-14-2Z, 2851-0-14-1Z, 2851-0-14-2Z, 2850-1-14-1Z, 2850-1-14-2Z, 2851-1-14-1Z, 2851-1-14-2Z, 2850-2-14-1Z, 2850-2-14-2Z, 2851-2-14-1Z, 2851-2-14-2Z, 2859-0-14-1Z, 2859-0-14-2Z, 2859-0-24-1Z, 2859-1-24-1Z, 2859-0-24-2Z, 2859-1-24-2Z, 2840-0-18-1Z, 2840-0-18-2Z, 2841-1-18-1Z, 2841-1-18-2Z, 2842-0-18-1Z, 2842-0-18-2Z, 2842-6-18-1Z, 2842-6-18-2Z, 2843-1-18-1Z, 2843-1-18-2Z, 2843-2-18-1Z, 2843-2-18-2Z, 2843-3-18-1Z, 2843-3-18-2Z, 2843-4-18-1Z, 2843-4-18-2Z, 2843-5-18-1Z, 2843-5-18-2Z, 2846-0-18-1Z, 2846-0-18-2Z, 2846-0-28-1Z, 2846-0-28-2Z, 2847-1-18-1Z, 2847-1-18-2Z, 2847-1-28-1Z, 2847-1-28-2Z, 2850-0-18-1Z, 2850-0-18-2Z, 2851-0-18-1Z, 2851-0-18-2Z, 2850-1-18-1Z, 2850-1-18-2Z, 2851-1-18-1Z, 2851-1-18-2Z, 2850-2-18-1Z, 2850-2-18-2Z, 2851-2-18-1Z, 2851-2-18-2Z, 2859-0-18-1Z, 2859-0-18-2Z, 2859-0-28-1Z, 2859-1-28-1Z, 2859-0-28-2Z, 2859-1-28-2Z,